Vasco Runtime Parameters
Description
Configuration settings of the Vasco Verifier.
May be used by
Properties
Allowed Token Types (
allowedTokenTypes) Description
This list defines all allowed types of tokens. If a token of different type is tried to be imported, an error is thrown. If this property is not set, all types are allowed.
Attributes
String-List
Optional
Allowed Application Names (
allowedApplicationNames) Description
This list defines all allowed application of vasco tokens to be imported. The first application to match will be used for all tokens to be imported. If this property is not set, the first application given by the vacman controller is used.
Attributes
String-List
Optional
I Time Window (
iTimeWindow) Description
Determines the acceptable time difference (in time steps) between a vasco token and the host system during authentication. The duration of a time step is characteristic to the used vasco token model.
The required number of time steps can be calculated as follows (rounded up to the next multiple of 2):
((Maximum period of inactivity in days * Maximum token clock drift per day)) * 2) / Time step of tokenWhere the maximum token clock drift per day is 2 seconds.
If this property is not set, the vacman controller default of 100 is used.
Attributes
Integer
Optional
Default value
23
YAML Template (with default values)
type: VascoRuntimeParameters
id: VascoRuntimeParameters-xxxxxx
displayName:
comment:
properties:
allowedApplicationNames:
allowedTokenTypes:
iTimeWindow: 23